ETC
ETC Echo Time Clock Echo Room Controller 4 Time Clock
☆☆☆☆☆
(0 reviews)
MPN: ERMCT4-G2|ETC
Lowest price (incl. delivery)
881,00 USD
- Offers
- 1
- Last updated
- för 3 månader sedan
| Säljare | Product price | Delivery | Totalt | Tillgänglighet | Updated | |
|---|---|---|---|---|---|---|
| Full Compass Systems | Product price 856,00 USD | Delivery 25,00 USD | Totalt 881,00 USD | Tillgänglighet Limited | Updated för 3 månader sedan | View offer |
Priser och tillgänglighet kan ändras. Senast uppdaterad: 24.08.2026 05:56.
MPN
ERMCT4-G2|ETC
Brand
ETC
ETC
0,0
☆☆☆☆☆
0 reviews
5★
0%
4★
0%
3★
0%
2★
0%
1★
0%
Product reviews
No reviews yet — be the first!
The Unison Echo™ Room Controller delivers an all-in-one power management solution for small to medium-sized spaces. With its versatile multi-space control, each output can be designated for a specific area, or multiple zones can be grouped within a single space. Its feed-thru power input design allows you to use a single power source for all relays or provide individual inputs for each relay based on system requirements. Each relay and 0-10V control remains independently operable, regardless of panel power setup.The Room Controller also adapts to control zones across multiple spaces, optimizing efficiency and minimizing hardware for compact systems.Designed for ease of integration, the Room Controller supports A/V interfaces, Demand Response from utilities, and features UL924 emergency bypass, making it a top choice for classrooms, offices, worship spaces, and general lighting control.Arena and Stadium suitesHouses of worshipEducationHospitalityHealthcare facilitiesOffice buildingsConference roomsMeeting roomsRetailFour- and eight-output options patchable to zones in multiple spacesA 20A fully rated relays for use with general purpose, tungsten, fluorescent, LED and plug loadsFully isolated 0-10V dimming for direct connection to dimming ballasts and LED drivers120 or 277VAC power input per zoneA/V integration via single contact inputDemand Response load sheddingSupports control stations, responsive controls and interfacesTopology free station bus with support for: 6 Elaho control products and 5 additional Elaho outputproducts (built-in station power supply)Up to 16 Elaho control products and 15 additional Elahooutput products (via external station power supply)Up to 500 meters (1640 feet) of control wire per systemGENERAL:UL, cUL and UL924 LISTEDRated for plenum installationFUNCTIONAL:Control for up to eight zones of relay control for lighting and plug loadsControl for up to eight zones of fully isolated 0-10V dimming control for LED drivers and fluorescent ballastsEach pair of power and 0-10V outputs can be patched to a space and zone via theElahoAccess mobile appContact Input responds to closure to place the lighting into a configurable, presentation-friendly preset, playback a lighting controlsequence, trigger room combine, or any other Elaho contact input functionUL924 emergency-lighting control via contact closure or integrated normal sense feedDemand Response input sent from a power company can enforce a maximum level per circuit while activeDemand Response commands can be transmitted to additional Elaho devices via the station busTime-of-day, astronomical and calendar events for the installed room, and up to 15 additional rooms (TimeClock versions only)Plug and Play: ready to go out of the box, no software or external programming requiredSupports up to 6 Elaho control products and 5 additional Elaho output products with internal Elaho Station Power SupplySupports up to 16 Elaho control products and 15 additional Elaho output products with external Elaho Station Power SupplyMECHANICAL:Constructed of 16-gauge cold-rolled steel, finished in fine-textured, black powder coatSupports wall-mount and plenum installationRotary dials for selection of space and starting zone numberClass one voltage barrier prevents access to line-voltage wiring with front panel removedOptional voltage divider allows for separation of normal and emergency circuits in a single controller where allowed by local codesDiscrete-feed mains power input: 100-277V Supports pass-through of input to multiple circuits up to the full circuit capacity of the controllerELECTRICAL:100-277V, 60Hz power input per circuitSupports 120V and 277V circuits within the same controller20-amp, fully-rated bi-state latching relay per output0-10VDC control rated for 100mA maximum sink per zone, fully isolated from groundSupports rising clamp screw terminal wiring connections for:Line-voltage relay power input, output and pass-through with support for 14-8AWG wireController power input and UL924 Sense circuit with support for 20-12AWG wireLow-voltage 0-10V dimming output with support for 22-16AWG wireSeparate normal power sense feed input for UL924 emergency lighting bypassUL924 emergency lighting contact input (NO/NC) with support for 22-16AWG wireContact Input (NO/NC) terminals with support for 22-16AWG wireDemand Response contact input (NO) with support for 22-16AWG wireControl connection for Belden 8471 wire (or approved equal)24V auxiliary power for integral timeclock with support for 22-16AWG wireBuilt-in station power supply with support for up to six control products and five external output productsOnboard status indicators for station power , UL924 input, Contact Input, DemandResponse, and Room Controller powerDip switch configuration for:Onboard Power Supply (on/off)Contact input type (NO/NC)UL924 sense feed active (on/off)UL924 input type (NO/NC)UL924 inclusion per circuit (on/off)MicroSD for field software upgradesUL and cUL ... ETC Echo T
Similar products